{"product_id":"kioxia-kioxia-cm7-v-128-tb-e3s-pci-express-50-nvme-bics-flash-tlc-kcm7xvje12t8","title":"Kioxia CM7-V 12.8 TB E3.S PCI Express 5.0 NVMe BiCS FLASH TLC","description":"\u003cstyle\u003etable.generic tr th {background: #eee;}\u003c\/style\u003e12800GB, E3.S, PCIe 5.0, NVMe 2.0, BiCS FLASH TLC, 110 g, SIE\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePCIe® 5.0, NVMe™ 2.0 specification compliant\u003c\/li\u003e\n\u003cli\u003eOpen Compute Project Datacenter NVMe™ SSD specification v2.0 support (not all requirements)\u003c\/li\u003e\n\u003cli\u003eForm factor: E3.S, 7.5 mm thickness\u003c\/li\u003e\n\u003cli\u003eProprietary KIOXIA architecture: controller, firmware and 112-layer BiCS FLASH™ 3D TLC\u003c\/li\u003e\n\u003cli\u003eDual-port design for high availability applications\u003c\/li\u003e\n\u003cli\u003eHigh performance with lower power consumption\u003c\/li\u003e\n\u003cli\u003ePower loss protection (PLP) and end-to-end data protection\u003c\/li\u003e\n\u003cli\u003eSuited for 24x7 enterprise workloads\u003c\/li\u003e\n\u003cli\u003eSecurity options: SIE, SED, FIPS SED\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDescription\u003c\/h2\u003e\u003cb\u003eEnterprise NVMe™ Mixed-use SSD\u003c\/b\u003e\u003cbr\u003eKIOXIA CM7-V Series is a mixed-use SSD that is optimized to support a broad range of enterprise applications and associated workloads, including high performance computing, online transaction processing, IoT and edge computing, media streaming. Built on PCIe® 5.0 and NVMe™ 2.0 technology, the CM7 Series SSDs deliver excellent performance up to 2,700K IOPS (random read) and 600K IOPS (random write).\u003cbr\u003e\u003cbr\u003eFeaturing KIOXIA 112-layer BiCS FLASH™ 3D TLC flash memory, the CM7-V Series of enterprise NVMe™ SSDs delivers 3 DWPD (Drive Writes Per Day) of endurance and supports storage capacities up to 12.8 TB, making them ideally suited for read and write mixed-use enterprise applications.\u003cbr\u003e\u003cbr\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"generic\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eHard drive\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSSD capacity\u003c\/td\u003e\n\u003ctd\u003e12.8 TB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory type\u003c\/td\u003e\n\u003ctd\u003eBiCS FLASH TLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eData transmission\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRead speed\u003c\/td\u003e\n\u003ctd\u003e13000 MB\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWrite speed\u003c\/td\u003e\n\u003ctd\u003e5300 MB\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRandom write (4KB)\u003c\/td\u003e\n\u003ctd\u003e470000 IOPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRandom read (4KB)\u003c\/td\u003e\n\u003ctd\u003e2000000 IOPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eEndurance\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMean time between failures (MTBF)\u003c\/td\u003e\n\u003ctd\u003e2500000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eFeatures\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003ePCI Express 5.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComponent for\u003c\/td\u003e\n\u003ctd\u003eServer\/workstation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNVMe\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNVMe version\u003c\/td\u003e\n\u003ctd\u003e2.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnd-to-End Data Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSSD capacity\u003c\/td\u003e\n\u003ctd\u003e12.8 TB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRead speed\u003c\/td\u003e\n\u003ctd\u003e13000 MB\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWrite speed\u003c\/td\u003e\n\u003ctd\u003e5300 MB\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory type\u003c\/td\u003e\n\u003ctd\u003eBiCS FLASH TLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRandom write (4KB)\u003c\/td\u003e\n\u003ctd\u003e470000 IOPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRandom read (4KB)\u003c\/td\u003e\n\u003ctd\u003e2000000 IOPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMean time between failures (MTBF)\u003c\/td\u003e\n\u003ctd\u003e2500000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSSD form factor\u003c\/td\u003e\n\u003ctd\u003eE3.S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarket segment\u003c\/td\u003e\n\u003ctd\u003eServer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH\/W PLP function\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget workload\u003c\/td\u003e\n\u003ctd\u003eMixed Use (MU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUse conditions\u003c\/td\u003e\n\u003ctd\u003eServer\/Enterprise\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003ePower\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower consumption (average)\u003c\/td\u003e\n\u003ctd\u003e25 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower consumption (standby)\u003c\/td\u003e\n\u003ctd\u003e5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating voltage\u003c\/td\u003e\n\u003ctd\u003e12 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003ePerformance\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003ePCI Express 5.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComponent for\u003c\/td\u003e\n\u003ctd\u003eServer\/workstation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNVMe\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNVMe version\u003c\/td\u003e\n\u003ctd\u003e2.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnd-to-End Data Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSSD capacity\u003c\/td\u003e\n\u003ctd\u003e12.8 TB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRead speed\u003c\/td\u003e\n\u003ctd\u003e13000 MB\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWrite speed\u003c\/td\u003e\n\u003ctd\u003e5300 MB\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory type\u003c\/td\u003e\n\u003ctd\u003eBiCS FLASH TLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRandom write (4KB)\u003c\/td\u003e\n\u003ctd\u003e470000 IOPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRandom read (4KB)\u003c\/td\u003e\n\u003ctd\u003e2000000 IOPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMean time between failures (MTBF)\u003c\/td\u003e\n\u003ctd\u003e2500000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eDesign\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComponent for\u003c\/td\u003e\n\u003ctd\u003eServer\/workstation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSSD form factor\u003c\/td\u003e\n\u003ctd\u003eE3.S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarket segment\u003c\/td\u003e\n\u003ctd\u003eServer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eWeight \u0026amp; dimensions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e76 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e110 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e112.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e7.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eOperational conditions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature (T-T)\u003c\/td\u003e\n\u003ctd\u003e0 - 73 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature (T-T)\u003c\/td\u003e\n\u003ctd\u003e-40 - 85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating relative humidity (H-H)\u003c\/td\u003e\n\u003ctd\u003e5 - 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating shock\u003c\/td\u003e\n\u003ctd\u003e1 G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating vibration\u003c\/td\u003e\n\u003ctd\u003e2.17 G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eTechnical details\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003ePCI Express 5.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature (T-T)\u003c\/td\u003e\n\u003ctd\u003e0 - 73 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature (T-T)\u003c\/td\u003e\n\u003ctd\u003e-40 - 85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating relative humidity (H-H)\u003c\/td\u003e\n\u003ctd\u003e5 - 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating shock\u003c\/td\u003e\n\u003ctd\u003e1 G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating vibration\u003c\/td\u003e\n\u003ctd\u003e2.17 G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSSD form factor\u003c\/td\u003e\n\u003ctd\u003eE3.S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarket segment\u003c\/td\u003e\n\u003ctd\u003eServer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"KIOXIA","offers":[{"title":"Default Title","offer_id":58912051200348,"sku":"KCM7XVJE12T8","price":9333.09,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0962\/1484\/3740\/files\/ZxXiz7l67kOWtjXq4ISbww.c-m_bcb16e41-8afc-47e0-915a-2d97e83b7dd0.jpg?v=1788339412","url":"https:\/\/multiplenetworks.co.uk\/products\/kioxia-kioxia-cm7-v-128-tb-e3s-pci-express-50-nvme-bics-flash-tlc-kcm7xvje12t8","provider":"Multiple Networks","version":"1.0","type":"link"}