{"product_id":"apc-smart-ups-rt-2200va-230v-marine-surtd2200xlim","title":"APC Smart-UPS RT 2200VA 230V - Marine","description":"\u003cstyle\u003etable.generic tr th {background: #eee;}\u003c\/style\u003eSmart-UPS RT 2200VA 230V - Marine\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIdeal for providing uninterrupted power in critical marine applications\u003c\/li\u003e\n\u003cli\u003eDNV type approved\u003c\/li\u003e\n\u003cli\u003eHot-swappable, front-accessible, user replaceable batteries\u003c\/li\u003e\n\u003cli\u003eManual bypass switch\u003c\/li\u003e\n\u003cli\u003eOperating temperature up to 55°C\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eReasons To Buy\u003c\/h2\u003e\u003ch4\u003ePredictive failure notification.\u003c\/h4\u003eProvides early-warning fault analysis ensuring proactive component replacement.\u003ch4\u003eWide input voltage range\u003c\/h4\u003eDesigned for harsh electrical environments to save battery life.\u003ch4\u003eGuarantees a consistently high level of power quality. Any disturbances on the distribution waveform are regenerated via the zero transfer time AC to DC then DC to AC conversion process. The battery is only used as a back-up source.\u003c\/h4\u003eAllows for reduced battery recharge time, prevents disturbances on the distribution system by correcting the power factor, protects the battery against damage caused by deep discharge and provides backfeed protection.\u003ch4\u003eFast battery charging capability\u003c\/h4\u003eAllows for reduced battery recharge time, prevents disturbances on the distribution system by correcting the power factor, protects the battery against damage caused by deep discharge and provides backfeed protection.\u003ch4\u003eEliminates humming and heat generated when powering tube lights and fans\u003c\/h4\u003eProvide easy-to-read status of the unit and utility power conditions.\u003ch4\u003eMicroprocessor controlled, 3-stage regulated charging ensures the fastest recharge times without decreasing battery life.\u003c\/h4\u003eProvide easy-to-read status of the unit and utility power conditions.\u003ch4\u003eLED Indicators\u003c\/h4\u003eProvide easy-to-read status of the unit and utility power conditions.\u003ch4\u003eSafeguards unit from damage by automatically turning it off in the event of a short circuit or overload.\u003c\/h4\u003eUser assignable inputs allow other equipment alarms to be monitored through the power system controller\u003ch4\u003eEnable management of your UPS by connecting it directly to the network.\u003c\/h4\u003eIf you are like most businesses, you want your systems up and running during your busiest hours. In order to accommodate your busy schedule, APC offers an option to schedule services off hours. We will work with you to find a time when servicing your system is least likely to impact your productivity, saving your business time and money.\u003ch4\u003eExcellent footprint\u003c\/h4\u003eSmall UPS footprint provides maximum usage of valuable electrical room floorspace\u003ch4\u003eAdvanced electrical features\u003c\/h4\u003eExcellent power conditioning, very low harmonic distortion through IGBT rectifier, input power factor correction, and high power efficiency\u003ch4\u003eIntuitive monitoring\u003c\/h4\u003eStep by step navigation and menu screens for critical system information and data. Information is easy to access and presented in a very intuitive way.\u003ch4\u003eProvides proactive notifications of changing power or unit conditions and provides the user the ability to remotely control PMU functions.\u003c\/h4\u003eHorizontal console port servers can be cascaded to manage up to 1,024 devices.\u003ch4\u003eSerial connectivity\u003c\/h4\u003eUse any Home Automation network to monitor and control the S20 through its RS-232 serial port. For information on how to communicate with the S20, see APC's Application Note #102. Crestron and AMX installers should visit their respective websites for information on how to integrate the S20 into those networks.\u003ch4\u003eReduces utility costs, generates less heat.\u003c\/h4\u003ePatent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.\u003ch4\u003eDynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.\u003c\/h4\u003eProvides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.\u003ch4\u003eSingle outlet group that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on\/off and non-critical load shedding.\u003c\/h4\u003eSimulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.\u003ch4\u003ePure sine wave output on battery\u003c\/h4\u003eSimulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.\u003ch4\u003eUL60950, CSA60950, IEC60950, EN60950 safety approvals. Meets IEC 61000-4-5 Immunity To Surge, and GR-1089-CORE, Section 4, Lightning and AC Power Faults standards.\u003c\/h4\u003eWarns when a battery is not available to provide backup power.\u003ch4\u003eDisconnected battery notification\u003c\/h4\u003eWarns when a battery is not available to provide backup power.\u003ch4\u003eSupplies utility power to the connected loads in the event of a UPS power overload or fault.\u003c\/h4\u003eRegistering license keys unlocks the features of the data center management software.\u003ch4\u003eAllows additional run time to be quickly added as needed.\u003c\/h4\u003eProvides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.\u003ch4\u003eProvides notification of changing utility power and UPS power conditions\u003c\/h4\u003eDelivers higher availability through redundant batteries.\u003ch4\u003eAutomatically starts up the connected equipment upon the return of utility power.\u003c\/h4\u003ePeriodic battery self-test ensures early detection of a battery that needs to be replaced.\u003ch4\u003ePeriodic battery self-test ensures early detection of a battery that needs to be replaced.\u003c\/h4\u003eReserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment\u003ch4\u003eEnsures compatibility with equipment that has different plug types.\u003c\/h4\u003eSimplifies installation and UPS maintenance while minimizing space requirements.\u003ch4\u003eFront-access servicing\u003c\/h4\u003eSimplifies installation and UPS maintenance while minimizing space requirements.\u003ch4\u003eEnsures clean, uninterrupted power to protected equipment when generator power is used.\u003c\/h4\u003eEnsures clean, uninterrupted power to protected equipment while batteries are being replaced\u003ch4\u003eHot-swappable batteries\u003c\/h4\u003eEnsures clean, uninterrupted power to protected equipment while batteries are being replaced\u003ch4\u003eMinimizes installation costs by enabling the use of smaller generators and cabling.\u003c\/h4\u003ePrevents unauthorized access to the UPS.\u003ch4\u003eProvides remote power management of the UPS over the network.\u003c\/h4\u003eIncreases total power capacity by using multiple uninterruptible power supplies simultaneously.\u003ch4\u003eProtects connected loads from surges, spikes, lightning, and other power disturbances.\u003c\/h4\u003eProvides early-warning fault analysis on batteries enabling timely preventive maintenance\u003ch4\u003eEnsures compatibility with different input frequencies.\u003c\/h4\u003eProtects the initial investment in the UPS when migrating from tower to rack-mount environment.\u003ch4\u003eEnsures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.\u003c\/h4\u003eProvides management of the UPS via a serial port.\u003ch4\u003eSerial connectivity\u003c\/h4\u003eProvides management of the UPS via a serial port.\u003ch4\u003eTemperature-compensated battery charging\u003c\/h4\u003eProlongs battery life by regulating the charge voltage according to battery temperature.\u003ch4\u003eIncreases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)\u003c\/h4\u003eFast, easy installation takes the guesswork out of configuration for first-time users\u003ch4\u003eIntelligent battery management\u003c\/h4\u003eMaximizes battery performance, life, and reliability through intelligent, precision charging.\u003ch4\u003eGives higher application availability by correcting poor frequency and voltage conditions without using the battery.\u003c\/h4\u003eBaseline data enables you to better understand your current situation and to measure improvements gained by infrastructure utilization and energy efficiency changes.\u003ch2\u003eDescription\u003c\/h2\u003eThe APC Smart-UPS RT is an online UPS with a power rating of 2200VA and output power capacity of 1540 watts. It includes multiple output connections such as IEC 60230 C19, IEC 60230 C13, and IEC Jumpers. This model is includes a lead-acid battery and is suitable for marine applications. The UPS features double conversion online technology and sine wave output.\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"generic\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003ePower\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput power\u003c\/td\u003e\n\u003ctd\u003e1540 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput operation voltage (min)\u003c\/td\u003e\n\u003ctd\u003e100 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput operation voltage (max)\u003c\/td\u003e\n\u003ctd\u003e280 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput operation voltage (min)\u003c\/td\u003e\n\u003ctd\u003e220 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput operation voltage (max)\u003c\/td\u003e\n\u003ctd\u003e240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge energy rating\u003c\/td\u003e\n\u003ctd\u003e555 J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e92%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmergency Power Off (EPO)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage Total Harmonic Distortion (THD)\u003c\/td\u003e\n\u003ctd\u003e3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest factor\u003c\/td\u003e\n\u003ctd\u003e3:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput power capacity\u003c\/td\u003e\n\u003ctd\u003e2.2 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003ePorts \u0026amp; interfaces\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable length\u003c\/td\u003e\n\u003ctd\u003e2.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC outlets quantity\u003c\/td\u003e\n\u003ctd\u003e10 AC outlet(s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC outlet types\u003c\/td\u003e\n\u003ctd\u003eC13 coupler, C19 coupler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of output IEC jumpers\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet LAN (RJ-45) ports\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003ePerformance\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaveform\u003c\/td\u003e\n\u003ctd\u003eSine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise level\u003c\/td\u003e\n\u003ctd\u003e55 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible alarm(s)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eFeatures\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin\u003c\/td\u003e\n\u003ctd\u003ePhilippines\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaveform\u003c\/td\u003e\n\u003ctd\u003eSine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput power\u003c\/td\u003e\n\u003ctd\u003e1540 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput operation voltage (min)\u003c\/td\u003e\n\u003ctd\u003e100 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput operation voltage (max)\u003c\/td\u003e\n\u003ctd\u003e280 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput operation voltage (min)\u003c\/td\u003e\n\u003ctd\u003e220 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput operation voltage (max)\u003c\/td\u003e\n\u003ctd\u003e240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge energy rating\u003c\/td\u003e\n\u003ctd\u003e555 J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e92%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmergency Power Off (EPO)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage Total Harmonic Distortion (THD)\u003c\/td\u003e\n\u003ctd\u003e3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise level\u003c\/td\u003e\n\u003ctd\u003e55 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest factor\u003c\/td\u003e\n\u003ctd\u003e3:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible alarm(s)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput power capacity\u003c\/td\u003e\n\u003ctd\u003e2.2 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eBattery\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery technology\u003c\/td\u003e\n\u003ctd\u003eSealed Lead Acid (VRLA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery recharge time\u003c\/td\u003e\n\u003ctd\u003e2.5 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement battery cartridge\u003c\/td\u003e\n\u003ctd\u003eAPCRBC140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery replacement accessibility\u003c\/td\u003e\n\u003ctd\u003eEnd-user\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eDesign\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin\u003c\/td\u003e\n\u003ctd\u003ePhilippines\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack capacity\u003c\/td\u003e\n\u003ctd\u003e3U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm factor\u003c\/td\u003e\n\u003ctd\u003eRackmount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct colour\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eCE; DNV; KCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable length\u003c\/td\u003e\n\u003ctd\u003e2.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eOperational conditions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature (T-T)\u003c\/td\u003e\n\u003ctd\u003e0 - 55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature (T-T)\u003c\/td\u003e\n\u003ctd\u003e-15 - 45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating relative humidity (H-H)\u003c\/td\u003e\n\u003ctd\u003e0 - 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage relative humidity (H-H)\u003c\/td\u003e\n\u003ctd\u003e0 - 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd\u003e0 - 3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-operating altitude\u003c\/td\u003e\n\u003ctd\u003e0 - 15000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eTechnical details\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003efront\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarmonized System (HS) code\u003c\/td\u003e\n\u003ctd\u003e85078000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal carbon footprint (kg of CO2e)\u003c\/td\u003e\n\u003ctd\u003e4342.273094382711\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance certificates\u003c\/td\u003e\n\u003ctd\u003eRoHS, REACH, WEEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003ePackaging data\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage dimensions (WxDxH)\u003c\/td\u003e\n\u003ctd\u003e603 x 980 x 347 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage weight\u003c\/td\u003e\n\u003ctd\u003e63.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eCertificates\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eCE; DNV; KCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaste Electrical and Electronic Equipment (WEEE) compliance\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance certificates\u003c\/td\u003e\n\u003ctd\u003eRoHS, REACH, WEEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eCertification\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaste Electrical and Electronic Equipment (WEEE) compliance\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eWeight \u0026amp; dimensions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e54.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage weight\u003c\/td\u003e\n\u003ctd\u003e63.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e432 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e660 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eLogistics data\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin\u003c\/td\u003e\n\u003ctd\u003ePhilippines\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustoms product code (TARIC)\u003c\/td\u003e\n\u003ctd\u003e8504409590\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarmonized System (HS) code\u003c\/td\u003e\n\u003ctd\u003e85078000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal carbon footprint (kg of CO2e)\u003c\/td\u003e\n\u003ctd\u003e4342.273094382711\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eOther features\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003efront\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput connection type\u003c\/td\u003e\n\u003ctd\u003eBS1363A British; IEC 60320 C20; Schuko CEE 7 \/ EU1-16P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (WxDxH)\u003c\/td\u003e\n\u003ctd\u003e130 x 660 x 432 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage dimensions (WxDxH)\u003c\/td\u003e\n\u003ctd\u003e603 x 980 x 347 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput connection type\u003c\/td\u003e\n\u003ctd\u003e8 IEC 60320C13; 2 IEC Jumpers; 2 IEC 60320C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal output voltage\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal input voltage\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"APC","offers":[{"title":"Default Title","offer_id":57041188684124,"sku":"SURTD2200XLIM","price":2211.7,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0962\/1484\/3740\/files\/7x4VWpOD90CoDwGIF-NkOg.c-m.jpg?v=1783606007","url":"https:\/\/multiplenetworks.co.uk\/products\/apc-smart-ups-rt-2200va-230v-marine-surtd2200xlim","provider":"Multiple Networks","version":"1.0","type":"link"}