{"product_id":"apc-netshelter-rack-pdu-advanced-switched-2u-3-phase-415v-414kva-60a-18-outlets-apdu11454sw","title":"APC NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets","description":"\u003cstyle\u003etable.generic tr th {background: #eee;}\u003c\/style\u003eNetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIdeal for AI and other high density applications\u003c\/li\u003e\n\u003cli\u003e4 in 1 combination outlet design acts as C13, C15, C19, and C21 in 50% of outlets\u003c\/li\u003e\n\u003cli\u003eEnhanced cybersecurity and EcoStruxureTM IT compatible\u003c\/li\u003e\n\u003cli\u003e1 year free subscription to Secure NMC3 System\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDescription\u003c\/h2\u003eAPC NetShelter Rack PDU Advanced (11K Series) provides reliable power distribution to IT equipment within server and\/or networking racks. PDU level power metering provides power visibility and notification of potential overload. 50 percent of outlets on model are designed as 4 in 1 combination outlets which can be used as either C13, C19, C15, or C21 to provide unparalleled deployment flexibility. Outlets on the PDUs are color coded and labeled by breaker. Live Swap the NMC3 to minimize downtime in the unlikely event of an NMC power event. The rack PDU integrates with EcoStruxure IT through an NMC3 and can be accessed and configured via web, SNMP, and command line interface (CLI). Rated to operate up to 60 C (140 F) at full load ensures reliability and availability even in today s high density deployments. One gigabit Ethernet\/network port (10\/100\/1000) enhances and standardizes network connectivity. Two link ports are available to cascade to up to 32 PDUs, with a network port sharing (NPS) feature to enable power sharing between Rack PDUs in the cascading group. Track or bill power usage confidently with 1% metering accuracy. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs have the following certifications: UL, CE, CSA, UKCA, Nemiko, PSE, KC, China RoHS, RCM, and CMIM. This model’s input power cord is 560P6 or 563P6 and features 9 count C13\/C15 and 9 count C13\/C15\/C19\/C21 outlets. A 9.8 foot (3 meter) input cord makes it easier for the PDU to reach the power supply.\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"generic\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eDesign\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eThree-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePDU types\u003c\/td\u003e\n\u003ctd\u003eSwitched\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eHorizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct colour\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack capacity\u003c\/td\u003e\n\u003ctd\u003e2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003ePorts \u0026amp; interfaces\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC outlets quantity\u003c\/td\u003e\n\u003ctd\u003e18 AC outlet(s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC outlet types\u003c\/td\u003e\n\u003ctd\u003eC13 coupler, C15 coupler, C19 coupler, C21 coupler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower plug\u003c\/td\u003e\n\u003ctd\u003eIEC309\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput connection type\u003c\/td\u003e\n\u003ctd\u003eIEC 309 60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eFeatures\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternational Protection (IP) code\u003c\/td\u003e\n\u003ctd\u003eIP44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eManagement features\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement platform\u003c\/td\u003e\n\u003ctd\u003eNMC3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003ePower\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal input voltage\u003c\/td\u003e\n\u003ctd\u003e415  3 phases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage\u003c\/td\u003e\n\u003ctd\u003e415 V AC 3 phases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum current\u003c\/td\u003e\n\u003ctd\u003e60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad capacity\u003c\/td\u003e\n\u003ctd\u003e41400 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC input frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of phases\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eCertificates\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaste Electrical and Electronic Equipment (WEEE) compliance\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance certificates\u003c\/td\u003e\n\u003ctd\u003eRoHS, REACH, WEEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eSustainability\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDoesn't contain\u003c\/td\u003e\n\u003ctd\u003eSilicone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eOperational conditions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature (T-T)\u003c\/td\u003e\n\u003ctd\u003e-5 - 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature (T-T)\u003c\/td\u003e\n\u003ctd\u003e-20 - 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage relative humidity (H-H)\u003c\/td\u003e\n\u003ctd\u003e5 - 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating relative humidity (H-H)\u003c\/td\u003e\n\u003ctd\u003e5 - 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-operating altitude\u003c\/td\u003e\n\u003ctd\u003e0 - 15240 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eWeight \u0026amp; dimensions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e16 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e443 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e750 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e85 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage width\u003c\/td\u003e\n\u003ctd\u003e600 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage depth\u003c\/td\u003e\n\u003ctd\u003e165 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage height\u003c\/td\u003e\n\u003ctd\u003e940 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage weight\u003c\/td\u003e\n\u003ctd\u003e22.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003ePackaging data\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage width\u003c\/td\u003e\n\u003ctd\u003e600 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage depth\u003c\/td\u003e\n\u003ctd\u003e165 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage height\u003c\/td\u003e\n\u003ctd\u003e940 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage weight\u003c\/td\u003e\n\u003ctd\u003e22.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eTechnical details\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDoesn't contain\u003c\/td\u003e\n\u003ctd\u003eSilicone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance certificates\u003c\/td\u003e\n\u003ctd\u003eRoHS, REACH, WEEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eCertification\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaste Electrical and Electronic Equipment (WEEE) compliance\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"APC","offers":[{"title":"Default Title","offer_id":58913425424732,"sku":"APDU11454SW","price":2955.3,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0962\/1484\/3740\/files\/hrQeMzXD502Emmau97XdSw.c-m_ba66746b-8b35-479a-b96e-04371f2f8c31.jpg?v=1788344246","url":"https:\/\/multiplenetworks.co.uk\/products\/apc-netshelter-rack-pdu-advanced-switched-2u-3-phase-415v-414kva-60a-18-outlets-apdu11454sw","provider":"Multiple Networks","version":"1.0","type":"link"}