{"product_id":"apc-inrow-rd-600mm-air-cooled-460-480v-60hz-with-humidifier-acrd601p","title":"APC InRow RD, 600mm Air Cooled, 460-480V, 60Hz, with humidifier","description":"\u003cstyle\u003etable.generic tr th {background: #eee;}\u003c\/style\u003eInRow RD, 600mm Air Cooled, 460-480V, 60Hz, with humidifier\u003ch2\u003eDescription\u003c\/h2\u003e\u003cb\u003eActive Airflow Control\u003c\/b\u003e\u003cbr\u003eMonitors and actively adjust cooling unit airflow in containment systems, while providing visibility to effective cooling to critical IT equipment.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eActive response control\u003c\/b\u003e\u003cbr\u003eMonitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and status of the unit is provided.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eAir filtration\u003c\/b\u003e\u003cbr\u003eRemoves dirt and other particulates from the intake air for cleaner supply air.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eArchitecturally neutral\u003c\/b\u003e\u003cbr\u003eUnobtrusive design and coloring, blends in with the surroundings.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eCapacity Control\u003c\/b\u003e\u003cbr\u003eCooling system will operate from 0 - 100% of the rated capacity to maintain rack inlet temperatures and reduce operational costs at varying heat loads.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eCasters\u003c\/b\u003e\u003cbr\u003eProvides flexibility to move the unit to wherever cooling is required.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eContainment system compatible\u003c\/b\u003e\u003cbr\u003eThe unit can be combined with a Rack or Hot Aisle Containment System to eliminate hot air mixing and maximize cooling efficiency\u003cbr\u003e\u003cbr\u003e\u003cb\u003eContinuous current monitoring\u003c\/b\u003e\u003cbr\u003ePermits a continuous monitoring of the compressor’s absorbed current to signal possible discrepancies with the default values (Optional).\u003cbr\u003e\u003cbr\u003e\u003cb\u003eDirect drive motors\u003c\/b\u003e\u003cbr\u003eStress on bearings is nearly eliminated, increasing useful life. Allows integral fan\/motor assembly to be factory balanced, which lowers vibration and expedites startup.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eEase of Use\u003c\/b\u003e\u003cbr\u003eSimplifies future planning by allowing side to side equipment to be placed anywhere in the data center.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eEasy to install\u003c\/b\u003e\u003cbr\u003eInnovative design allows for fast, easy installation by almost anybody.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eEfficiency\u003c\/b\u003e\u003cbr\u003eIncreases the capacity of the air conditioner by supplying a warmer return air temperature.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eElectronic expansion valve\u003c\/b\u003e\u003cbr\u003eRefrigerant flow optimization at any load and temperature conditions. Continuous indirect refrigerant charge monitoring\u003cbr\u003e\u003cbr\u003e\u003cb\u003eElectronically Commutated Fans\u003c\/b\u003e\u003cbr\u003eProvide the highest efficiency and reduce total power consumption by matching the airflow requirements to the heat load of the data center.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eEnclosure system compatible\u003c\/b\u003e\u003cbr\u003eSpecifically designed to work with Netshelter Enclosures.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eFan guards\u003c\/b\u003e\u003cbr\u003eA safety measure that provides protection from the fan opening by covering the inlet.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eFault-tolerant fan system\u003c\/b\u003e\u003cbr\u003eIn the event of a fan failure, the remaining fan(s) will continue to operate.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eField replaceable components\u003c\/b\u003e\u003cbr\u003eFans and electronics module can be readily replaced without uninstalling the unit.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eFlexibility\u003c\/b\u003e\u003cbr\u003eSupport for varying aisle widths, rack heights, rack depths, and single rows. Supports hot and cold aisle containment\u003cbr\u003e\u003cbr\u003e\u003cb\u003eFront service access\u003c\/b\u003e\u003cbr\u003eThe system has full service, front access for routine servicing of components. Front access also narrows the footprint of the system making it possible for units to be placed side by side.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eGreen Refrigerant\u003c\/b\u003e\u003cbr\u003eEnvironmentally friendly refrigerant that can offer LEED points.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eHardwire capable\u003c\/b\u003e\u003cbr\u003eFor installations where hard wiring is required or prefered.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eHead pressure control\u003c\/b\u003e\u003cbr\u003eModulates refrigerant head pressure to protect from coil freeze.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eHigh Sensible-to-Total Cooling Ratio\u003c\/b\u003e\u003cbr\u003eAchieved by careful sizing of heat exchanger coils.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eHorizontal airflow pattern\u003c\/b\u003e\u003cbr\u003eRemoves heat close to the source of generation in the hot aisle and distributes cold air to the front of the racks in the cold aisle.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eIncreased capacity\u003c\/b\u003e\u003cbr\u003eHigher rate of heat removal allows more equipment to be installed in each rack.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eLocal area network\u003c\/b\u003e\u003cbr\u003eCreates a shared control between all the available resources for maximum energy efficiency and controlled management of the group during emergency situations\u003cbr\u003e\u003cbr\u003e\u003cb\u003eMinimizes Air Mixing\u003c\/b\u003e\u003cbr\u003eDelivers cool, conditioned air directly to the inlet of IT equipment.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eModular strategy\u003c\/b\u003e\u003cbr\u003eModular design of the mechanical and control systems allow for gradual build-up of the cooling infrastructure to match the cooling demand of the facility. This greatly reduces CAPEX expeditures and provides deferred investment throughout the life of the facility.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eNetwork interface\u003c\/b\u003e\u003cbr\u003eProvides management by connecting the device directly to the network with a dedicated IP address, avoiding the need for a proxy such as a server. Management is available via Web browser, Telnet or SSH. Notification features inform you of problems as they occur.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eOperational efficiency\u003c\/b\u003e\u003cbr\u003eWarmer entering air temperatures reduce both the required amount of humidification and the demand for costly reheat.\u003cbr\u003e\u003cbr\u003e\u003cb\u003ePredictable cooling\u003c\/b\u003e\u003cbr\u003ePlacing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.\u003cbr\u003e\u003cbr\u003e\u003cb\u003ePredictive failure notification\u003c\/b\u003e\u003cbr\u003eMaximizes system availability by providing early warning of required fan or filter replacement.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eProgrammable input\/output contacts\u003c\/b\u003e\u003cbr\u003eAllows device contacts to be connected to the air conditioner and mapped to customer outputs or system alarms.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eRack Inlet Temperature Control\u003c\/b\u003e\u003cbr\u003eReduces the risk of hot spots at the rack level\u003cbr\u003e\u003cbr\u003e\u003cb\u003eReal-Time Capacity Monitoring\u003c\/b\u003e\u003cbr\u003eReal-time display of current and available cooling.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eRear containment\u003c\/b\u003e\u003cbr\u003eEnsures server exhaust air is returned to the InRow cooling units for maximum cooling predictability.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eRow-based architecture\u003c\/b\u003e\u003cbr\u003eCaptures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eScalable Design\u003c\/b\u003e\u003cbr\u003eModular design provides scalable solutions to add cooling as demand increases.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSmall Footprint\u003c\/b\u003e\u003cbr\u003eEfficient use of space with a small footprint provides the ability for the unit to be placed in a corner or even installed into a partitioned space.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eTemperature Display\u003c\/b\u003e\u003cbr\u003eMonitors and displays temperature to prevent overheating.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eTouch-screen GUI\u003c\/b\u003e\u003cbr\u003eEnables easy configuration, full monitoring, and event logging\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"generic\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eFeatures\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct colour\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eWeight \u0026amp; dimensions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e600 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e1070 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e1991 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e402 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003ePackaging data\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage width\u003c\/td\u003e\n\u003ctd\u003e850 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage depth\u003c\/td\u003e\n\u003ctd\u003e1137 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage height\u003c\/td\u003e\n\u003ctd\u003e2166 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage weight\u003c\/td\u003e\n\u003ctd\u003e447 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"APC","offers":[{"title":"Default Title","offer_id":58912880099676,"sku":"ACRD601P","price":20799.4,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0962\/1484\/3740\/files\/PIzZNni8rUCqHB1seZRZLA.c-m_e32e5313-15bf-45c0-aa26-6d701b1eec7c.jpg?v=1788342603","url":"https:\/\/multiplenetworks.co.uk\/products\/apc-inrow-rd-600mm-air-cooled-460-480v-60hz-with-humidifier-acrd601p","provider":"Multiple Networks","version":"1.0","type":"link"}